Xeltek SuperPro L+ 48-pin Universal Programmer (Parallel Port) |
 |
|
 |
|
|
| Â |
The Superpro L+ is a low-cost Universal Programmer supporting over 3,900+ devices including
many popular (E)EPROMs, FLASH, CPLDs, GALs and Microcontrollers. The programmer features
a 48-pin Zero Insertion Force (ZIF) socket allowing it to support any device up to 48 pins in
Dual-in-line (DIL) package.
Support is offered for the popular 8051 and Microchip PIC microcontrollers making this programmer
ideal for microcontroller development. The Superpro L+ programmer connects to the PC Parallel
(LPT) port yielding very fast data transfer speeds. The software is powerful and yet easy-to-use and
support all the standard programming operations.
DISCONTINUED PRODUCT
|
| Â |
|
|
|
 |
PC Driver Software |
|
- File: Load and save file in binary, Intel (extended) Hex, Motorola S or Tektronics (extended) Hex format. Multiple load, format conversion, relocation etc...
-
DOS shell, Change directory, Print, Quit
-
Buffer: HEX-ASCII Edit, Fuse Map Edit, Checksum, Swap, Vector Table edit
-
Select: Bidirectional search device by device name or by manufacturer name
-
Device: Blank Check, Read, Program, Verify, Security, Fuse, Erase, Word format select and funtions related to specific device
-
Test: TTL/CMOS Test, Memory Test, Vector Test, Test Pattern Edit, Auto Identify TTL/CMOS Device
-
Others: Macro, Options, Environment etc...
-
This shoftware is designed to work with Windows 98, ME and 2000. Correct operation on Windows XP is possible but is not guaranteed.
|
 |
Device Support |
|
- Supports 3,900+ devices, including most E(E)PROM,Series E(E)PROM. FLASH
-
GAL, EP3xx/6xx/9xx, PEEL, PALCE, PLUS, PLS, PLH, PLC, ATV, ATF, CPL, 85Cxxx, 5Cxxx, DS12xx
-
Microcontrollers 87xx / 89xx / Z86Exx / TMS320xxx / D77Pxx / D78Pxx / PD75xxx / HD6370xxx / PIC16Cxx/17Cxx, and PSD3XX
-
Please note: The Device Support list for this programmer is fixed. New devices will not be added in the future.
|
 |
Hardware Features |
|
- Connects to PC via PC Printer Port (LPT) Interfaces (parallel communication, uses address 278H,378H, 3BCH)
-
Easy interface to LAPTOP, PC, PS/2 or compatibles
-
48-pin Zero Insertion force (ZIF) Socket
-
External mains power supply adaptor
-
High speed programming, cost-effective Hardware and Flexible Software
|
 |
Device Update Policy |
|
- The Superpro L+ programmer is considered an entry product with basic support.
-
Device update is infrequent and there is no set schedule available. New devices will not be added in the future.
-
Please check the Device Support List and make sure the devices in your application are supported at present time
-
You (can get the latest software) may download the current software version free of charge - See the Downloads link
|
 |
Hardware and Electrical Specification |
|
- PC Connection: Parallel Printer Port (LPT)
-
AC Adapter : Input AC 220V or 110V
-
Device socket : One 48 pin ZIF socket
-
Power supply : Input AC 100 to 240V , Output : DC 12V @ 1.5 Amp
-
Programmer Dimension : 7 3/4" L x 5 1/2" W x 3/4" H
-
Shipping Weight : 1.8 Kg
|
 |
Feature Comparison with Superpro Z programmer |
|
|
The Superpro L+ programmer is the replacement programmer for the now discontinued Superpro Z programmer.
A comparison of these two programmers is detailed in the table below:
Rlink 2software Version 903550x [ REAL × 2024 ]
Renault R-LINK 2 software version 9.0.35.50x provides a stable update enhancing Android Auto, Apple CarPlay, and interface responsiveness while resolving issues like random reboots. The update is typically installed via USB on compatible hardware, with users advised to verify eligibility for their specific vehicle. To check for this update, visit the Renault Connect Portal. Update for R-LINK 2 - Renault Connect
Minimum Requirements:
- OS: Windows 7 Professional (32-bit) or Windows Embedded Standard 7. Note: 64-bit systems require explicit driver signature override.
- Processor: Intel Atom or equivalent (single core, 1.6 GHz).
- RAM: 1 GB (2 GB recommended for data logging sessions over 24 hours).
- Disk Space: 450 MB for the core application plus 2 GB for log storage.
- Dependencies: Microsoft .NET Framework 3.5 SP1, Visual C++ 2008 Redistributable.
Here is everything you need to know about the 9.0.35.50x update, from its key features to how you can get it. What’s New in Version 9.0.35.50x? rlink 2software version 903550x
Feature 2 — Offline diagnostics & local logs
- User story: As a user, I can view diagnostics without sending data externally.
- Acceptance criteria:
Significance of RLink 2 Software Version 903550X Renault R-LINK 2 software version 9
- Ensure resumable transfer endpoint accessible; increase transfer timeout and monitor disk space.
: If the update fails during the initial reset phase, the unit can enter a "black screen" state. This is often caused by incompatible hardware (Micom version too low) or removing the USB stick too early. Update Procedure Update for R-LINK 2 - Renault Connect OS: Windows 7 Professional (32-bit) or Windows Embedded
90 → Major architecture revision (driver core).
355 → Build number in the release cycle.
0X → Minor patch identifier (X can be 0 through 9, though 0, 2, and 5 are most common).
|  |
| Product Information |
| Xeltek SuperPro L+ 48-pin Universal Programmer (Parallel Port) |
| Xeltek |
|
XEL-SuperproL+ |
| Discontinued Product |
|
| Â |
 |
| Â |
| Â |
 |
| Â |
|
|
|
|
|